KR3000 Series Graphic Recorders
KR3000 Series are network-compatible paperless recorders with high performance and high operating function employed high visibility 12.1" TFT color LCD display and touch panel operation system. High speed of sampling rate 100ms for 48 points and high accuracy of ±0.1% were realized, and measured data is stored into internal memory and maximum 2GB compact flash card (CF card). As it can be monitored by a web browser display on several computers on intranet or internet, FTP transfer of data file and E-mail notification are also available. |
|
Large sized 12.1" TFT color LCD display
Large-sized high visibility display with various display functions. Real time/Historical trend screen, Bar-graph screen, Data screen are selectable for various applications.
Combination display for selected 4 screens is available. It is easy to switch to individual screen by touching panel. |
Large capacity of data memory and various recording method
Compact flash card (CF card) slot is equipped as standard external memory. Large capacity storage of maximum 2GB is available.
Various data storing methods are selectable such as schedule programming by time of day and time of date, recording start-up by external signal and event, and data logging of before and after trigger points for alarm. |
Multi points recording with high speed/high accuracy
High-speed recording of approximately 100ms for 48 points and high accuracy of ±0.1% were realized. Stable measuring and recording are possible with high speed.
High withstand voltage of 1000V AC between input channels. |
Easy operating and programming without manuals
Easy operating by dedicated keys for each function and touch panel.
USB port is prepared in front compartment. Setting file and data file are stored in USB memory stick. |
LAN network capability
Various networked environment such as remote monitoring by browser, FTP server, FTP client and E-mail notification are applied as Ethernet is equipped as standard. |
Analyzing/data acquisition application software
It is easy to replay and edit the recorded data file. Replay display has functions of vertical/horizontal trend, circular trend, and also wave-analyzing and marking by using the cursor. |
KR3120-N0A |
12points/100ms |
KR3140-N0A |
24points/100ms |
KR3160-N0A |
36points/100ms |
KR3180-N0A |
48points/100ms |
12 points, 24 points, 36 points and 48 points |
Universal
DC voltage: ±13.8mV, ±27.6mV, ±69.0mV, ±200mV, ±500mV, ±2V, ±5V*, ±10V*, ±20V*, ±50V*
(*with built-in voltage divider)
DC current: With external shunt resistor (sold separately)
Thermocouple: B, R, S, K, E, J, T, N, PtRh40-PtRh20, W-WRe26, WRe5-WRe26, Platinelâ
Ą, NiMo-Ni, CR-AuFe, U, L
Resistance thermometer: Pt100, JPt100, Pt50, Pt-Co |
Refer to the table of measuring range, accuracy ratings and display resolution |
K, E, J, T, N, Platinelâ
Ą--- ±0.5șC or less
R, S, W-WRe26, WRe5-WRe26, NiMo-Ni, CR-AuFe, U, L --- ±1.0 șC or less |
100ms: Approximately 100ms for all points
1s: Approximately 300ms for all points |
Disconnection of input signal is detected on thermocouple and resistance thermometer input. UP/DOWN/DISABLE is selectable for each input |
Range/scale is selectable when DC voltage/current is programmed |
FIR filter |
Thermocouple input (burnout disable)/DC voltage input (±2V or less) --- 1k ohm or less
DC voltage input (±5V or more) --- 100 ohm or less
Resistance thermometer --- Per wire 10 ohm or less(same resistance for 3 wires) |
DC voltage, thermocouple input --- Approximately 1 M ohm |
DC voltage input (±2V or less)/thermocouple input (burnout disable) --- ±10VDC
DC voltage input (±5V to ±50V) --- ±60VDC |
1000V AC or more between each channel (High strength semiconductor relay used)
(B terminal of resistance thermometer is shorted inside between channels.) |
120dB |
50dB |
136MB |
CF card (Up to 2GB) |
100, 200, 500ms
1, 2, 3, 5, 10, 15, 20, 30s
1, 2, 3, 5, 10, 15, 20, 30, 60min |
Measured data --- File name (group name), time of day, month and year of recording start, tag, measured data, alarm status/types, makertext
Setting parameter |
Binary/CSV type |
Manual start/stop (dedicated key operation)
Schedule (designation for time of day and date)
Trigger signal (alarm event, digital input)Data logging of before and after trigger points
* Pre-trigger is selectableMeasuring numbers of pre-trigger --- Max 950 data |
6 groups of 56 points/group can be programmed (Up to Total of 128 points) |
Up to 4 alarms can be programmed per channel |
Upper limit, lower limit, differential upper limit, differential lower limit (deadband is selectable), abnormal data |
Setup range of alarm delay --- 1 to 3600 seconds |
AND/OR selectable |
Refer to option specification |
12.1â TFT color LCD |
Measured data display
(Trend screen, Data screen, Bar-graph screen)
Historical trend display(simultaneous display with Real-time trend is available)
Information display(alarm display, marker list, file list)
Setting screen(alarm, computation, memory, system, maintenance, communication, etc.) |
48 colors selectableDisplay screen--- 6 screens (6 groups)
Display points --- Maximum 56 points/screen
Time axis direction --- Vertical or horizonta
lLine width --- 1 to 5 dot selectable
Scale display --- 4 scales
Tag/data display --- Show/hide selectableMarker display |
Display screen --- 6 screens (6 groups)
Display points --- Maximum 56 points/screen
Display contents --- Measured value, channel/tag, unit, alarm status |
48 colors selectable
Display screen --- 6 screens (6 groups)
Display points --- Maximum 56 points/screen
Display direction --- Vertical or horizontal
Scale display --- 1 scale |
Alarm display (alarm activation/released history display)
Marker list
File list (group data file list display)
Unit information (Model, serial no., option, etc.) |
Auto/manual OFF function
Brightness --- 4 levels adjustment |
Ethernet (10BASE-T/100BASE-TX) |
Data file can be read from the network computer |
Transfer a data file to a network server |
The time can be synchronized to the time of SNTP server |
Conformed to HTTP1.0 --- Display the alarm, information of maintenanceby browser software (InternetExplorer5.0 or later, NetScape6.0 or later, Opera7 or later) |
E-Mail notification at specified time for alarm activation
Report data at specified time is selectable from all registered dataNotification address --- Maximum 8 contacts |
USB2.0 (full speed), host function
USB memory stick is used as external memory (Some USB memory stick can not be used.) |
Touch panel/dedicated key |
HOME, MENU, DISP, MARKER, SCROLL, CURSOR, START, STOP, DIRECTION keys, ENTER, ESC |
Simple recording settings --- Common setting to all channelsParameter programming for all channels together, recording cycle, selection settings |
Input/computation programming --- Input parameter, computation parameter
DISP Settings --- Data channel parameter, group parameter, common parameter (combination display, trend vertical/horizontal)
Alarm settings File settings (6 individual files) --- Storing method settings Marker text settings
System settings --- Communication, clock, maintenance, key lock, password, screen, etc. |
Operating screen selection --- Trend, data, bar-graph, historical trend, alarm display, maker list
Display selection on each screen --- Group 1 to 6 selectable |
100 to 240V AC (universal power supply) 50/60Hz |
65VA |
Ambient temperature --- 21 to 25șC,
Ambient humidity --- 45 to 65%RH
Power voltage --- 100V AC±1.0%
Power frequency --- 50/60Hz±0.5%
Attitude --- Left/right 0°, forward/backward 0°
Warm-up time --- Longer than 30 minutes |
Ambient temperature --- 0 to 50șC
Ambient humidity --- 20 to 80%RH
Power voltage --- 90 to 264V AC
Power frequency --- 50/60Hz±2%
Attitude --- left/right 0°, forward tilting 0°,
backward tilting 0° to 20° |
Ambient temperature --- -20 to 60 șC
Ambient humidity --- 5 to 90%RH (No dew condensation)
Vibration --- 10 to 60Hz 4.9m/ S2 (0.5G) or less
Impact --- 392m/S2 (40G) or less |
Ambient temperature --- -20 to 60șC
Ambient humidity --- 5 to 90%RH (No dew condensation) |
Setups and data are backed up by flash memory.
Clock:Lithium battery backs up RAM
(Minimum 5 years) |
Secondary terminals and protective conductor terminals ---20M ohm or more at 500V DC
Primary terminals and protective conductor terminals --- 20M ohm or more at 500V DC
Primary and secondary terminals ---20M ohm or more at 500V DC
Primary terminals: power terminals (L,N), alarm output terminals
Secondry terminals: measuring input terminals, digital input terminals, communications terminals |
Secondary terminals and protective conductor terminals ---1 minute at 500V AC
Primary terminals and protective conductor terminals ---1 minute at 1500V AC
Primary and secondary terminals --- 1 minute at 2300V AC
Primary terminals:power terminals (L,N), alarm output tereminals Secondry terminals: measuring input terminals, digital input terminals communications terminals |
Front bezel --- ABS resin
Case --- Steel |
Front bezel --- Black (equivalent to Mussel N3.0)
Case --- Painting color, gray (equivalent to Mussel N7.0) |
7.2kg |
Panel mounting |
Power terminals/protective conductor terminals/communications terminals --- M4.0
Measuring input terminals/alarm output terminals/digital input terminals --- M3.5 |
Real-time trend screen
Displays data (measured and virtual) of selected group. Vertical trend and horizontal trend selectable.
|
Bar-graph screen
Displays data (measured and virtual) of selected group. Combination display with real-time trend is available.
|
Data screen
Displays data (measured and virtual) of selected group. Simultaneous display of alarm status.
|
Dual trend screen
2 split display for real-time trend and historical trend. Scroll available for historical trend.
|
Information screen
|
HOME setting screen
|
Channel setting screen
|
Schedule setting screen
|
PS Sheet |
KR3000 Series |
PSE-354B |
|
Instruction Manual |
KR3000 Series |
INE-815 |
|
|